Hardware
The cRIO system with its rugged design and good value architecture consisting of very different measurement modules, the intelligent FPGA chassis and a high-performance real time controller, offers a high degree of flexibility for your measurement tasks.
- Synchronous acquisition with up to 28 channels with minimal space consumption
- Various signal types may be acquired (voltage, IEPE (ICP) conditioning, bridge amplifier for strain gauges)
- Continuous or intermittent recording, trigger condition may be defined individually for any channel
- Measurement of acceleration, velocity, displacement, force, strain, rpm, analogue and digital signals
Components

NI cRIO-9014 - real time controller with 128-MB-DRAM and 2-GB memory
- Processor with 400 MHz, non-volatile memory with 2 GB, 128-MB-DRAM
- 10/100BaseT ethernet port with embedded web server and file server with a remote panel user interface
- Full-speed USB host port for USB flash connection and memory devices
- dual 9 to 35 VDC inputs
- Operating temperature range from - 40° C to + 70° C

NI cRIO-9104 embedded CompactRIO chassis with 8 slots and 3 million gates
- Reconfigurable embedded chassis with 8 slots for CompactRIO-I/O modules
- RIO-FPGA with 3 million gates for ultimate processing power
- Operating temperature range from - 40° C to + 70° C

NI 9237 - 4 channels, 24-bit resolution, ±25 mV/V simultaneous bridge module
- For strain measurement, force measurement etc.
- Supports half bridge or full bridge in four and six-wire operation.
- Calibration conforms with NIST
- 4 simultaneously sampled analogue inputs, maximum sample rate of 50 kS/s
- Programmable half and full bridge completion, up to 10 V internal excitation
- Transient isolation 1000 Vrms.
- Operating temperature range from - 40° C to + 70° C

NI 9239 - analogue input module with 4 channels and 24 bits
- Channel to channel isolation 250Vrms
- 50 kS/s per channel simultaneous inputs
- Anti aliasing filters
- ±10 V input range
- Operating temperature range from - 40° C to + 70° C

NI 9233 - 4 channels, ±5 V, 50 kS/s per channel, 24 bit resolution
- IEPE signal conditioning (2 mA) for microphones, accelerometers etc.
- Maximum sample rate of 50 kS/s, AC-coupled (0.5 Hz)
- 24 bit resolution, 102 dB dynamic range, anti aliasing filter
- 4 simultaneously sampled analogue inputs, input range of ±5 V
- Operating temperature range from - 40° C to + 70° C